Nanomaterial effects on C. elegans body size

Nanomaterial: RGO: Reduced graphene oxide
Concentration: 1.04 µg/cm² (dispersant: DI water).
Control: DI Water
Test Method

Trial 1
  Worm length
average (normalized)
S.D. n p value
(Student's t-test)
Control 1 0.08 222 -
Nanomaterial 1.01 0.04 28 0.49
Trial 2
  Worm length
average (normalized)
S.D. n p value
(Student's t-test)
Control 1 0.08 201 -
Nanomaterial 0.94 0.06 77 1.6e-9
Trial 3
  Worm length
average (normalized)
S.D. n p value
(Student's t-test)
Control 1 0.09 223 -
Nanomaterial 0.95 0.06 62 2.6e-6