Nanomaterial effects on C. elegans body size

Nanomaterial: RGO: Reduced graphene oxide
Concentration: 0.52 µg/cm² (dispersant: DI water).
Control: DI Water
Test Method

Trial 1
  Worm length
average (normalized)
S.D. n p value
(Student's t-test)
Control 1 0.08 201 -
Nanomaterial 0.95 0.07 66 1.5e-6
Trial 2
  Worm length
average (normalized)
S.D. n p value
(Student's t-test)
Control 1 0.09 223 -
Nanomaterial 0.96 0.08 47 0.0099